Composite

Part:BBa_K389423:Experience

Designed by: Jonas Aretz   Group: iGEM10_Bielefeld-Germany   (2010-10-11)

This experience page is provided so that any user may enter their experience using this part.
Please enter how you used this part and how it worked out.

Applications of BBa_K389423

Characterization tests

Cultivation was done by induction with acetosyringone at 50 µM. Controls were not induced sensitivity tuner devices as well as induced and not induced native system (K389015; without tuning elements). Induction was done upon inoculation. Measuring point for amplification factor calculation was OD 1.0.


Results

Three sensitivity tuned vir-gene sensing systems were obtained: K389421, K389422 and K389423 distinguishing by the amplification level of luc transcription.

Figure 1: Amplification factor of induced, 50 µM acetosyringone (red) and not induced (green) modified sensitivity tuner K389421, K389422 and K389423, standard deviation shown.

The amplification factor was received by apply K389015 as reference. Amplification calculation was done by normalizing relative luminescence units emitted from luciferase per OD. Output-signal amplification is in the induced contructs (red) K389422 and K389423 100 and respectively 200 fold higher than in not induced controls (green). An exception is K389422 were induced and not induced system revealed analog results. Corresponding to data of iGEM Team, Cambridge 2009, K389423 (originated from I746390) shows the highest amplification rate of all tested sensitivity tuners. Our results indicate to higher amplification rate of K389421 than K389422 of 100 fold under induced conditions. The controls also show high basal transcription rates.

Because there is small difference visible in induced and not induced system and basal transcription rates are high, we assume that the sensitivity tuning constructs are not well applicable for luciferase measurements.

For further theory click [http://2010.igem.org/Team:Bielefeld-Germany/Project/Theory#Read_out_system read out system]



For test results click [http://2010.igem.org/Team:Bielefeld-Germany/Results/Tests#BBa_K389421.2C_BBa_K389422.2C_BBa_K389423:_Sensitivity_Tuner_amlified_Vir-test_system sensitivity tuner amlified Vir-test system]

User Reviews

UNIQe02f457cbeefd75f-partinfo-00000000-QINU UNIQe02f457cbeefd75f-partinfo-00000001-QINU